351
11
Detail B
Protective Device Guard for Measuring Station
The system’s gripping and transfer station is safeguarded using panel frames with welded grids in a custom
RAL colour all around the station. The in-feed area and the measuring cell are protected by panel frames
with polycarbonate and cover panels. A space-saving folding door is installed in addition to the swing
door.
Detail A Detail B è Page 258
Safety interlock
Safety interlock with tower bolt, folding door locking
device, reliable lock monitoring and integrated CES-AP
electronics. This interlock does not require a special
evaluation unit. The interlock meets safety category
4 and PL e according to EN ISO 13849-1 when installed
horizontally, i.e. with the top facing downwards.
It has two failsafe semiconductor outputs
and an OUT signal output, in addition to clocked
safety outputs.
Fence clip
mk 2544
Fence clips can be used to quickly mount welded
grids onto Series 40 profiles. You simply hammer
the clip into the profile slot. To adequately secure
the welded grid in the profile frame, the fence clips
should be a maximum of 200 mm from the corners
and 520 mm from each other.
Detail A
Application Examples